Retrofit and new build under-floor heating systems integrated with low impact solar and biomass heating technologies.
Underfloor heating that can be installed as an integral part of an energy efficient home heating system. These systems make use of hot water generated by a combination of solar and bio-mass burner heated water with gas boiler backup if needed. Systems can be designed to utilise just one or all of these water heating sources.

Our underfloor heating systems are suitable for integration in new-build floor constructions and retro-fit systems in existing homes where internal ceiling heights allow for installations directly over existing wooden and concrete floors.

Anyone with special skiils and experience in balanced ecological systems are invited to add a 'how to' page to the eco-build info pages. Include descriptions and photos that best present your craft so that others with an interest can dig deeper and ultimately refine and improve the process.

Please feel free to add your pages in your native tonque since most browsers offer the viewer the possibility of instant web page translation to your selected mother tongue.





Under-floor Heating Systems


 ALT TEXT 2.

 ALT TEXT 1.

 ALT TEXT 2.

 ALT TEXT 1.

 ALT TEXT 2.

 ALT TEXT 1.

 ALT TEXT 2.

 ALT TEXT 1.

 ALT TEXT 2.

 ALT TEXT 1.

 ALT TEXT 2.







Underfloor Heating General Principals
The principals of under floor heating (also referred to as radiant heating) remain the same whether using electric or water systems. Heated floors act as efficient low-level radiators, radiating heat energy evenly into the room, gently warming the living space through a combination of radiant energy and heat conduction. In a modern, well insulated room, where heat loss factors have been taken into consideration, underfloor heating can act as the primary heat source: in the majority of cases eliminating the need for radiators.

Radiators convect heat into the room, creating rising currents of warm air concentrating at the ceiling level: this type of convection heating is wasteful and inefficient. Underfloor heating operates by radiating heat energy into the room at the floor level, gently and evenly warming the room: this method of heating is cheaper to run than radiator heating by up to 20%.

Modern underfloor heating is unobtrusive, allowing the freedom to position furnishings and units wherever you want, without having to compromise on design considerations that would otherwise be the case with conventional, wall mounted radiators. By eliminating old fashioned, inefficient radiators from the walls, the days of having to arrange furniture in the warmest spots in the room, close to radiators, are over.

Finally, with radiator heating, no matter how warm the ambient temperature in the room, the floor will always be uncomfortably cold, particularly where hard floor surfaces like tiles or laminate flooring has been chosen. The great advantage of underfloor heating is that this form of heating not only warms the room more efficiently at a lower cost, it also gives a luxurious Mediterranean feel to walk on; tiles and laminate floors now have a welcoming warm surface.

Water Underfloor Heating
The principals of piped water under floor heating relies on a continuous feed of pumped, circulating warm water – via a mixing valve to an adjusted lower temperature - through the sub-floor substrate; usually a 65-75mm cement screed, but equally can be installed over timber sub-floors.

In the case of a cement screeded sub-floor, this thermal mass becomes a background heat store. To offset the drop in temperature of the cement screed during overnight or off peak times, the thermostat settings can be adjusted to a lower level (setback temperature) to retain the temperature of the screed to within a few degrees below daytime settings - typically 3 - 4°C lower.

If the underfloor heating were to be turned off completely the cement screed would cool down too far below optimum background temperature: depending on time of the year, this would delay room warm up times by up to 2 hours. In order to prevent the screed thermal mass dropping too low, it is more efficient to maintain the floor at a constant lower temperature. Using this setback method will quickly bring the floor heating system back up to normal operating, ambient temperature, thermostat settings.

Water under floor heating has many advantages over traditional radiator heating. When the pipework is incorporated within the screeded sub-floor at the outset, the installation costs are no more than a radiator system; coupled with the added savings on operating costs, the payback time for a water underfloor heating system is financially viable.

Floor Finishes and Coverings
Underfloor heating systems are suitable for almost any floor finish; however, it is important to understand the effect of different flooring types. Whichever floor covering is chosen it will become part of heating system, radiating heat energy into the room. Each floor covering will have a greater or lesser degree of efficiency of the underfloor heating, depending on the type of material chosen.

Different floor coverings have different levels of thermal resistance (a measure of the insulation properties of materials): these values are known as the R-value, also referred to as the TOG rating. Manufacturers of continental quilts and carpets use TOG ratings as a measure of the insulation qualities of their products - the higher the TOG values the higher the thermal resistance.

Tiled Floors
In simple terms, harder and denser floor coverings like ceramic or stone tiles all have very low TOG values and as such, less of an insulating effect over the underfloor heating, allowing a rapid transfer of heat energy thorough their structure. The effect of the low TOG rating of these floor types is that their surfaces are excellent emitters of thermal energy (referred to as thermal conductivity or W/mK) - these flooring surfaces will provide the optimum efficiency over an under floor heating system.

Engineered Wood, Timber & Laminate Floors
Engineered wood, timber and laminate floorings have naturally higher TOG values, and depending on thickness, will slow thermal movement through the material: consequently, these materials do not perform as efficiently as tiled floors when radiating heat energy into the room. However, provided the maximum board thickness does not exceed 22mm (or 0.15m²K/W) these floor types will give excellent results when used over underfloor heating.

Vinyl Floors
Vinyl flooring types generally have a low TOG rating and as such offer little thermal resistance to the heat transfer - these floor types will work efficiently with underfloor heating.

Carpet Floors
Carpets and underlays on the other hand are excellent insulators and will generally have higher TOG values: as such these materials will resist the thermal energy being generated by the underfloor heating. If carpets are the preferred choice, select those with low TOG ratings: underlays should also be chosen with low insulation properties.

The thicker the carpet and underlay the longer the warm up time; this will have the effect of slowing the heat transfer of the flooring into the room - these floor types are considered to be the least efficient of all the floor coverings.

If you are unsure whether a certain type of floor covering is suitable for under floor heating, we strongly recommend consulting with the retailer or manufacturer. If in doubt we would advise that specific information should be obtained from the proposed flooring supplier or manufacturer to assess the suitability of the flooring type.